mlx%d: controller initialisation in progress... mlx%d: initialisation complete |
| The controller firmware is performing/has completed initialisation. |
mlx%d: physical drive %d:%d not responding | The drive at channel:target is not responding; it may have failed or been removed. |
mlx%d: spinning up drives... | Drive startup is in progress; this may take several minutes. |
mlx%d: configuration checksum error | The array configuration has become corrupted. |
mlx%d: mirror race recovery in progress mlx%d: mirror race on a critical system drive mlx%d: mirror race recovery failed |
| These error codes are undocumented. |
mlx%d: physical drive %d:%d COD mismatch | Configuration data on the drive at channel:target does not match the rest of the array. |
mlx%d: system drive installation aborted | Errors occurred preventing one or more system drives from being configured. |
mlx%d: new controller configuration found | The controller has detected a configuration on disk which supersedes the configuration in its nonvolatile memory. It will reset and come up with the new configuration. |
mlx%d: FATAL MEMORY PARITY ERROR | Firmware detected a fatal memory error; the driver will not attempt to attach to this controller. |
mlx%d: unknown firmware initialisation error %x:%x:%x | An unknown error occurred during initialisation; it will be ignored. |
|
mlx%d: cant allocate scatter/gather DMA tag mlx%d: cant allocate buffer DMA tag mlx%d: cant allocate s/g table mlx%d: cant make initial s/g list mapping mlx%d: cant make permanent s/g list mapping mlx%d: cant allocate interrupt mlx%d: cant set up interrupt |
| A resource allocation error occurred while initialising the driver; initialisation has failed and the driver will not attach to this controller. |
mlx%d: error fetching drive status | The current status of all system drives could not be fetched; attachment of system drives will be aborted. |
mlx%d: device_add_child failed mlx%d: bus_generic_attach returned %d |
| Creation of the system drive instances failed; attachment of one or more system drives may have been aborted. |
mlxd%d: detaching... | The indicated system drive is being detached. |
mlxd%d: still open, cant detach | The indicated system drive is still open or mounted; the controller cannot be detached. |
mlx%d: flushing cache... | The controller cache is being flushed prior to detach or shutdown. |
|
mlx%d: ENQUIRY failed - %s mlx%d: ENQUIRY2 failed mlx%d: ENQUIRY_OLD failed mlx%d: FLUSH failed - %s mlx%d: CHECK ASYNC failed - %s mlx%d: REBUILD ASYNC failed - %s mlx%d: command failed - %s |
| The controller rejected a command for the reason given. |
mlx%d: I/O beyond end of unit (%u,%d > %u) mlx%d: I/O error - %s |
| An I/O error was reported by the controller. |
mlx%d: periodic enquiry failed - %s | An attempt to poll the controller for status failed for the reason given. |
mlx%d: mlx_periodic_enquiry: unknown command %x | The periodic status poll has issued a command which has become corrupted. |
mlxd%d: drive offline mlxd%d: drive online mlxd%d: drive critical |
| The system disk indicated has changed state. |
mlx%d: physical drive %d:%d reset mlx%d: physical drive %d:%d killed %s "mlx%d: physical drive %d:%d error log: sense = %d asc = %x asq = %x" "mlx%d: info %4D csi %4D" |
| The drive at channel:target has been reset, killed for the given reason, or experienced a SCSI error. |
mlx%d: unknown log message type %x mlx%d: error reading message log - %s |
| An error occurred while trying to read the controllers message log. |
mlxd%d: consistency check started mlx%d: consistency check completed |
| A user-initiated consistency check has started/completed. |
mlx%d: drive rebuild started for %d:%d mlx%d: drive rebuild completed |
| A user-initiated physical drive rebuild has started/completed. |
mlx%d: background check/rebuild operation started mlx%d: background check/rebuild operation completed |
| An automatic system drive consistency check or physical drive rebuild has started/completed. |
mlx%d: channel %d pausing for %d seconds mlx%d: channel %d resuming mlx%d: pause command failed - %s mlx%d: pause failed for channel %d mlx%d: resume command failed - %s mlx%d: resume failed for channel %d |
| Controller/channel pause operation notification. (Channel pause is not currently supported on any controller.) |
mlx%d: controller wedged (not taking commands) | The controller is not responding to attempts to submit new commands. |
mlx%d: duplicate done event for slot %d mlx%d: done event for nonbusy slot %d |
| Corruption has occurred in either the controllers onboard list of commands or in the driver. |
|