DESCRIPTION
The sio driver provides support for NS8250-, NS16450-, NS16550 and NS16550A-based EIA RS-232C ( CCITT V.24) communications interfaces. The NS8250 and NS16450 have single character buffers, the NS16550A has 16 character FIFO input and output buffers. Input and output for each line may set to one of following baud rates; 50, 75, 110, 134.5, 150, 300, 600, 1200, 1800, 2400, 4800, 9600, 19200, 28800, 38400, 57600, or 115200. Your hardware may limit your baud rate choices.
The driver supports multiport cards. Multiport cards are those that have one or more groups of ports that share an Interrupt Request (IRQ) line per group. Shared IRQs on different cards are not supported. Frequently 4 ports share 1 IRQ; some 8 port cards have 2 groups of 4 ports, thus using 2 IRQs. Some cards allow the first 2 serial ports to have separate IRQs per port (as per DOS PC standard).
Some cards have an IRQ control register for each group. Some cards require special initialization related to such registers. Only AST/4 compatible IRQ control registers are supported. Some cards have an IRQ status register for each group. The driver does not require or use such registers yet. To work, the control and status registers for a group, if any, must be mapped to the scratch register (register 7) of a port in the group. Such a port is called a master port.
The driver supports controller based PCI modems. The 3Com FaxModem PCI and the Advantec 56k Voice Messaging PCI FaxModem are the only cards supported. WinModems, softmodems, hfc modems and any other modems that are not controller based are not supported.
The flags keyword may be used on each device sio line in the kernel configuration file to disable the FIFO on 16550A UARTs (see the synopsis). Disabling the FIFO should rarely be necessary.
The flags keyword must be used for all ports that are part of an IRQ sharing group. One bit specifies IRQ sharing; another bit specifies whether the port does not require AST/4 compatible initialization. The minor number of the device corresponding a master port for the group is encoded as a bitfield in the high byte. The same master port must be specified for all ports in a group.
The irq specification must be given for master ports and for ports that are not part of an IRQ sharing group, and not for other ports.
In the synopsis, flags 0x701 means that the 8th port (sio7) is the master port, and that the port is on a multiport card with shared IRQs and an AST/4 compatible IRQ control register.
flags 0xb05 means that the 12th port (sio11) is the master port, and that the port is on a multiport card with shared IRQs and no special IRQ control register.
Which port is the master port depends on the card type. Consult the hardware documentation of your card. Since IRQ status registers are never used, and IRQ control registers are only used for AST/4 compatible cards, and some cards map the control/status registers to all ports in a group, any port in a group will sometimes do for the master port. Choose a port containing an IRQ status register for forwards compatibility, and the highest possible port for consistency.
Serial ports controlled by the sio driver can be used for both callin and callout. For each port there is a callin device and a callout device. The minor number of the callout device is 128 higher than that of the corresponding callin port. The callin device is general purpose. Processes opening it normally wait for carrier and for the callout device to become inactive. The callout device is used to steal the port from processes waiting for carrier on the callin device. Processes opening it do not wait for carrier and put any processes waiting for carrier on the callin device into a deeper sleep so that they do not conflict with the callout session. The callout device is abused for handling programs that are supposed to work on general ports and need to open the port without waiting but are too stupid to do so.
The sio driver also supports an initial-state and a lock-state control device for each of the callin and the callout "data" devices. The minor number of the initial-state device is 32 higher than that of the corresponding data device. The minor number of the lock-state device is 64 higher than that of the corresponding data device. The termios settings of a data device are copied from those of the corresponding initial-state device on first opens and are not inherited from previous opens. Use stty(1) in the normal way on the initial-state devices to program initial termios states suitable for your setup.
The lock termios state acts as flags to disable changing the termios state. E.g., to lock a flag variable such as CRTSCTS, use stty crtscts on the lock-state device. Speeds and special characters may be locked by setting the corresponding value in the lock-state device to any nonzero value.
Correct programs talking to correctly wired external devices work with almost arbitrary initial states and almost no locking, but other setups may benefit from changing some of the default initial state and locking the state. In particular, the initial states for non (POSIX) standard flags should be set to suit the devices attached and may need to be locked to prevent buggy programs from changing them. E.g., CRTSCTS should be locked on for devices that support RTS/CTS handshaking at all times and off for devices that do not support it at all. CLOCAL should be locked on for devices that do not support carrier. HUPCL may be locked off if you do not want to hang up for some reason. In general, very bad things happen if something is locked to the wrong state, and things should not be locked for devices that support more than one setting. The CLOCAL flag on callin ports should be locked off for logins to avoid certain security holes, but this needs to be done by getty if the callin port is used for anything else.
FILES